CONSTRUCTION FIRE DOORS
Stone Foundation of the Fire Safety
Saajos is one of the most remarkable fire and safety door producers in the field of construction industry around the Baltic Sea. Typical targets are hotels, shopping centres, hospitals, industrial plants and public buildings. Our target is to offer only top quality engineering and products.
Hidden
Stone Foundation of the Fire Safety
Saajos Oy is one of the most remarkable fire and safety door producers in the field of construction industry around the Baltic Sea. Typical targets are hotels, shopping centres, hospitals, industrial plants and public buildings. Our target is to offer only top quality engineering and products.
HINGED FIRE DOORS
Most common type of fire door. Used in passageways of buildings between the fire compartments. Saajos Fire Doors are made of non-combustible materials that prevent fire spreading for certain time. Features are indicated according to the classification standard SFS-EN 13501-2:
- Capability to prevent fire and flame spread are tested acc. to fire test standard SFS-EN 1634-1
- Mechanical strength is tested acc. to SFS-EN 14600
Size limitation in fire classified doors
FIRE RATING | MINIMUM | MAXIMUM |
---|---|---|
EI2120 (double door) | 13,1 x 17,28M | width 29,87M and height 26,44M, however, surface area max. 7,1 m2 |
EI2120 (single leaf) | 6,1 x 17,28M | width 12M and height 23M |
EI260 (double door) | 10,1 x 5,5M | width 22,9M and height 25,2M, however, surface area max. 5,2 m2 |
EI260 (single leaf) | 5 x 5,3M | width 12M and height 23M, however, surface area max. 2,45 m2 |
EI230 (double door) | 12,6 x 18M | width 28,6M and height 27,5M, however, surface area max. 7,1 m2 |
EI230 (single leaf) | 6,5 x 18M | width 13M and height 24M |
Equipment
- door leafs are made of zinc-coated steel plates
- screw-fastening frame with cover lists, made of zinc-coated steel plates
- lift hinges of steel
- fitting for Abloy 4190T lock
- reinforcements for pull and closer
- cover caps for fastening holes
- quick latch installed (double doors only)
- instructions for installation, handling, maintenance and painting
Accessories
- kick plates
- alternative quick latch (double doors)
- different door closer types
- window, max 460 x 560 mm
- fitting and tubing for electric lock, door magnet, wires and lead cover, locations and models acc. to type approvals
- fitting for security lock
- type approved frame with gasket, U-value < 1,0 W/m2K
- alternative surface handling and powder painting, standard shades
Other accessories and iron mongery according to tender.
SLIDING FIRE DOORS
Sliding fire door is needed when the construction opening is large. The door is installed on the wall on top of the opening where it moves along the wall on a rail. Features below are indicated according to the classification standard SFS-EN 13501-2: :
- Capability to prevent fire and flame spread are tested acc. to fire test standard SFS-EN 1634-1
Maximum size for fire classified door leaf (width x height): 6000 mm x 5162 mm
E 120-class door doesn’t require safety distance
Equipment
- door leaf is made of zinc-coated steel plates
- electro-galvanized slide rail with fasteners
- electro-galvanized rollers with bearings
- fire emergency closing equipment:
- PSL manual emergency closer for max. 600 kg normally open doors
- E6LDC fire emergency closer for automatically functioning doors
- E6LDC fire emergency closer with force controlled buttons
- smoke and/or heat detector
- cup or bar puller
- lower guide and door stopper
- protective painting on non-galvanized steel parts
- installation and maintenance instrutions
Accessories
- cut-outs for monitoring equipment
- kick plates
- crush barrier
- painting
FIRE HATCHES
Fire hatches are tested and classified according to the requirements for hinged fire doors. Features are indicated according to the classification standard SFS-EN 13501-2:
- Capability to prevent fire and flame spread are tested acc. to fire test standard SFS-EN 1634-1
- Mechanical strength is tested acc. to SFS-EN 14600
EI260: construction opening max. 1150 mm wide and 2400 mm high.
Equipment
- door leafs are made of zinc-coated steel plates
- screw-fastening frame with cover lists, made of zinc-coated steel plates
- lift hinges of steel
- fitting for Abloy 4190T lock
- reinforcements for pull and closer
- cover caps for fastening holes
- threshold same profile as the other parts of the frame
- instructions for installation, handling, maintenance and
Accessories
- kick plates
- different door closer types
- fitting and tubing for electric lock, door magnet, wires and lead cover, locations and models acc. to type approvals
- alternative surface handling and powder painting, standard shades
PRESSURE:PROOF FIRE DOORS
Pressure-proof fire doors have been designed and tested to withstand the stress of a pressure impact in addition to “standard fire door”. Doors are made of non-combustible materials that prevent fire spreading for certain time. Features are indicated according to the classification standard SFS-EN 13501-2:
- Capability to prevent fire and flame spread are tested acc. to fire test standard SFS-EN 1634-1
- Mechanical strength is tested acc. to SFS-EN 14600
- Pressure impact has been tested at Laboratory of air handling technology at VTT Expert Services, Finland
- HFO-doors between 0,01 – 0,4 bar
- HPO-doors with explosive pressure 1,0 bar
- Flying particles and hurricane test have been performed for HPO door according to standards ASTM E 1886-05 and ASTM 1996-09
HFO = EI260
Minimum size classified: HFO: 5 x 15,75M
Maximum size classified: HFO: width 22,8M and height 25,2M, however, surface area max. 5,2 m2
Equipment
- door leafs are made of zinc-coated steel plates
- screw-fastening frame with cover lists, made of zinc-coated steel plates
- lift hinges of steel
- 3-point lock
- reinforcements for pull and closer
- cover caps for fastening holes
- quick latch installed (double doors only)
- instructions for installation, handling, maintenance and painting
Accessories
- kick plates
- alternative quick latch (double doors)
- different door closer types
- fitting for security lock
- alternative surface handling and powder painting, standard shades
Other accessories and iron mongery according to tender.
BURGLARY RESISTANT FIRE DOORS
Locations that require burglar resistance in addition to fire safety. Burglary resistance features are expressed according to the classification standard SFS-EN 1627 and fire-proof features according to the classification standard SFS-EN 13501-2:
- Capability to prevent fire and flame spread are tested acc. to fire test standard SFS-EN 1634-1
- Mechanical strength is tested acc. to SFS-EN 14600
- Burglary resistance is tested acc. to SFS-EN 1628, 1629 and 1630, class 3
Size limitations of fire classified doors
Minimum size as classified fire door: 5 x 15,75M
Maximum size as classified fire door: 11,5 x 24,15M
Equipment
- door leafs are made of zinc-coated steel plates
- screw-fastening frame with cover lists, made of zinc-coated steel plates
- lift hinges of hardened steel
- lock cases acc. to SFS-ENV 1627
- reinforcements for pull and closer
- safety pins
- instructions for installation, handling, maintenance and painting
Accessories
- kick plates
- different door closer types
- fitting and tubing for electric lock, door magnet, wires and lead cover, locations and models acc. to type approvals
- alternative surface handling and powder painting, standard shades
Other accessories and iron mongery according to tender.
ACOUSTIC FIRE DOORS
Locations that require airbourne sound insulation in addition to fire safety. Acoustic features are expressed according to the classification standard ISO 717-1 and fire-proof features according to the classification standard SFS-EN 13501-2:
- Capability to prevent fire and flame spread are tested acc. to fire test standard SFS-EN 1634-1
- Mechanical strength is tested acc. to SFS-EN 14600
- Airbourne sound insulation is tested acc. to ISO 140-3, RW = 34 dB
Size limitations of fire classified doors
Minimum size as classified fire door: 5 x 15,75M
Maximum size as classified fire door: 11,5 x 24,15M
Equipment
- door leafs are made of zinc-coated steel plates
- screw-fastening frame with cover lists, made of zinc-coated steel plates
- lift hinges of steel
- fitting for Abloy 4190T lock
- reinforcements for pull and closer
- cover caps for fastening holes
- instructions for installation, handling, maintenance and painting
Accessories
- kick plates
- different door closer types
- window, max 460 x 560 mm
- fitting and tubing for electric lock, door magnet, wires and lead cover, locations and models acc. to type approvals
- fitting for security lock
- alternative surface handling and powder painting, standard shades
Other accessories and iron mongery according to tender.
GLAZED FIRE DOORS
Profile construction fire door. Used in passageways of buildings between the fire compartments. Glazed Fire Doors are made of non-combustible materials that prevent fire spreading for certain time. Features are indicated according to the classification standard SFS-EN 13501-2:
- Capability to prevent fire and flame spread are tested acc. to fire test standard SFS-EN 1634-1
- Mechanical strength is tested acc. to SFS-EN 14600
Size limitation in fire classified doors according to the type approvals.
Equipment
- frame and door parts are made of steel profiles
- glazed with glasses in accordance to the type approval
- welded steel lift-hinges with bearings
- Fitting for Abloy profile lock
- reinforcements for pull and closer
- quick latch installed (double doors only)
- instructions for installation, handling, maintenance and painting
Accessories
- kick plates
- alternative quick latch (double doors)
- different door closer types
- fitting and tubing for electric lock, door magnet, wires and lead cover, locations and models acc. to type approvals
- fitting for security lock
- alternative surface handling and powder painting, standard shades
Other accessories and iron mongery according to tender.
BULLET-PROOF DOORS
MODULE | OPENING IN WALL | OUTER DIMENSION OF FRAME D X F | B X H | CLEAR OPENING Y X Z |
---|---|---|---|---|
9 x 21 M | 900 x 2100 | 960 x 2130 | 840 x 2065 | 800 x 2045 |
10 x 21 M | 1000 x 2100 | 1060 x 2130 | 940 x 2065 | 900 x 2045 |
MODULE | WEIGHT (DOOR + FRAME) AND TYPE CODE | |||
---|---|---|---|---|
310.1 | 309.3 | 308.1 | K308/415A | |
9 x 21 M | 130 kg | 140 kg | 200 kg | 215 kg |
10 x 21 M | 140 kg | 150 kg | 220 kg | 235 kg |
![]() |
Equipment
- Door leaves made of zinc-coated steel plate, not painted
- Screw-fastening frame with cover lists, made of electro-galvanised steel
- Hardened lift-up steel hinges with greas nipples
- Fitting for Abloy 4190T -lock
- Reinforcements for door closer and puller
- Mounting and painting instructions
Accessories
- Kick plates
- Different types of door closers
- Different types of latches for double doors
- Fitting for security lock
- Different types of handles, pullers etc. mounted
- Fitting for electric lock, monitoring equipment and lead cover
- Different types of surface finishing
Other accessories and iron mongery according to tender.
CONSTRUCTION DIVISION DOWNLOADS
Selected drawings and documents for construction industry products (pdf)
CERTIFICATES AND APPROVALS FOR CONSTRUCTION INDUSTRY
CE-marked sliding doors and external doors
- EI160 sliding fire doors: DoP (in Finnish), certificate 1336-CPR-0192
- EI260 Hinged external doors, single and double: DoP (in Finnish), certificate 1336-CPR-0193 (in Finnish)
- Glazed external fire doors made of EI60 Jansen Janisol profiles: DoP, certificate 1336-CPR-0201
- Glazed external fire doors made of EI30 Jansen Janisol profiles: DoP, certificate 1336-CPR-0200
- Hinged door, single and double: DoP (in Finnish)
- Sliding door: Dop (in Finnish)
- Glazed door made of Forster Unico profiles: DoP (in Finnish)
Hinged solid doors and hatches
- EI230 steel fire hatch (in Finnish): 22001514-THTOD EI30-luukku
- Single leaf hinged steel door with a window EI230 (in Finnish): EUFI29-19006251-THTOD
- Double leaf fire door EI230 (in Finnish): EUFI29-21002136-THTOD
- Single leaf fire door EI260 (in Finnish): EUFI29-20005918-THTOD
- Double leaf fire door EI260 (in Finnish): EUFI29-20005917-THTOD
- Single leaf fire door EI2120 (in Finnish): EUFI29-19001612-THTOD
- Double leaf fire door EI2120 (in Finnish): EUFI29-20004202-THTOD
Glazed profile fire doors
- EI260 Glazed single and double leaf fire door (in Finnish): VTT-RTH-00012-13
- EI230 Glazed single and double leaf fire door (in Finnish): EUFI29-20004587-THTOD
- EI260 Glazed single and double leaf fire door (in Finnish): VTT-RTH-00080-16
- E30 Glazed single and double leaf fire door (in Finnish): EUFI29-20002603-THTOD Forster Presto E30
- Doors made of Janisol 2 EI 30 -system steel profiles (in Finnish): EUFI29-20004875-THTOD
- Doors made of Janisol C4 EI260 -system steel profiles (in Finnish): EUFI29-20005916-THTOD
- Doors made of Forster Fuego Light 60 -system steel profiles (in Finnish): EUFI29-21005961-THTOD

MARINE FIRE DOORS
Our products travel thousands of nautical miles with the luxury cruisers, passenger ferries and cargo ships every day, ensuring the utmost safety of the passengers and crew members.

INDUSTRIAL SPECIALITIES
In the most demanding industrial environments the products may be subject to special requirements like pressure or burglary resistance in addition to fire safety. We can find the perfect solution for every client no matter how small or big they are.